Sun Fire
V20z Server User Guide
Part No. 817-5248-10
March 2004, Revision A
Vedere la pagina 0
1 2 3 4 5 6 ... 105 106

Sommario

Pagina 1 - V20z Server User Guide

Sun Microsystems, Inc.www.sun.com Submit comments about this document at: http://www.sun.com/hwdocs/feedback Sun Fire ™ V20z Server User Guide Par

Pagina 2

x Sun Fire V20z Server User Guide • March 2004 Contacting Sun Technical Support If you have technical questions about this product that are not answe

Pagina 3 - Contents

C-2 Sun Fire V20z Server User Guide • March 2004C.1 diags cancel tests C.1.1 CommandAccess: AdministratorsDescription: Cancels one or more diagnostic

Pagina 4

Appendix C Diagnostics Commands C-3C.1.3 diags get stateC.1.3.1 CommandAccess: AdministratorsDescription: Returns the state of the platform diagnostic

Pagina 5

C-4 Sun Fire V20z Server User Guide • March 2004C.2 diags get testsC.2.1 CommandAccess: AdministratorsDescription: Returns data describing the diagnos

Pagina 6

Appendix C Diagnostics Commands C-5C.3 diags run testsC.3.1 CommandAccess: AdministratorsDescription: Submits one or more diagnostic tests for executi

Pagina 7 - Using UNIX Commands

C-6 Sun Fire V20z Server User Guide • March 2004The following data displays after a test is run: Submitted Test Name Test Handle Test Result (for

Pagina 8 - Typographic Conventions

Appendix C Diagnostics Commands C-7C.4 diags start C.4.1 CommandAccess: AdministratorsDescription: Starts the service processor and platform diagnosti

Pagina 9 - Application Title Part Number

C-8 Sun Fire V20z Server User Guide • March 2004C.5 diags terminate C.5.1 CommandAccess: AdministratorsDescription: Terminates all diagnostics tests a

Pagina 10 - Sun Welcomes Your Comments

1-1 CHAPTER 1 Introduction to the Sun Fire V20z Server The Sun Fire V20z server is an AMD Opteron™ processor-based enterprise-class 1U 2P server. Th

Pagina 11

1-2 Sun Fire V20z Server User Guide • March 2004 1.1 Applications The Sun Fire V20z server is ideal for the following applications: Web or applicat

Pagina 12 - 1.2 Features

Chapter 1 Introduction to the Sun Fire V20z Server 1-3 1.3 Server Management Strong server management capabilities are crucial to maintaining mission

Pagina 13 - 1.3 Server Management

1-4 Sun Fire V20z Server User Guide • March 2004 1.4 Hardware System Orientation Prior to performing any service procedures, become familiar with the

Pagina 14 - 1.4.1 Front and Back Panels

Chapter 1 Introduction to the Sun Fire V20z Server 1-5 FIGURE 1-2 depicts the back panel of the Sun Fire V20z server: FIGURE 1-2 Back Panel 1.4.2 O

Pagina 15 - 1.4.2 Operator Panel

1-6 Sun Fire V20z Server User Guide • March 2004 TABLE 1-2 shows the operator panel buttons that are used to navigate through the menu options.The B

Pagina 16 - Operator Panel Buttons

Chapter 1 Introduction to the Sun Fire V20z Server 1-7 TABLE 1-3 lists the operations you can perform from the operator panel: TABLE 1-3 Operator

Pagina 17 - Menu Menu Options Description

1-8 Sun Fire V20z Server User Guide • March 2004 Dump SP Invokes the Troubleshooting Dump Utility (TDU) which captures the following information and

Pagina 18

Chapter 1 Introduction to the Sun Fire V20z Server 1-9 1.4.3 Front and Back Panel LEDs TABLE 1-4 describes the LEDs on the front panel of the Sun Fi

Pagina 19

PleaseRecycle Copyright 2004 Sun Microsystems, Inc., 4150 Network Circle, Santa Clara, California 95054, U.S.A. All rights reserved.Sun Microsystems,

Pagina 20 - 1.4.4 System Components

1-10 Sun Fire V20z Server User Guide • March 2004 1.4.4 System Components FIGURE 1-3 shows the locations of the components inside the Sun Fire V20z

Pagina 21 - 1.6 Replaceable Components

Chapter 1 Introduction to the Sun Fire V20z Server 1-11 1.5 Ship Kit The Sun Fire V20z server is supplied with the components shown in Table 1-6. 1.

Pagina 22 - Component Part Number

1-12 Sun Fire V20z Server User Guide • March 2004TABLE 1-7 Sun Fire V60x Server Replaceable Components Component Part NumberCPU/Heatsink Kit• Optero

Pagina 23 - 1.7 Integrated Mirroring

Chapter 1 Introduction to the Sun Fire V20z Server 1-131.7 Integrated MirroringWith traditional mirroring (or RAID1), a drive has its data duplicated

Pagina 24

1-14 Sun Fire V20z Server User Guide • March 2004

Pagina 25 - 2.1 Powering On the Server

2-1CHAPTER2Powering On and Configuring the ServerThis chapter contains instructions on powering up and configuring the server BIOS. Before powering on t

Pagina 26 - 2.2 Powering Off the Server

2-2 Sun Fire V20z Server User Guide • March 2004Follow these steps to boot the server:1. Ensure that the AC power cord is plugged into the power conne

Pagina 27 - Terminal

Chapter 2 Powering On and Configuring the Server 2-32.3 Escape Sequences for Remote Console TerminalIf you are accessing your Sun Fire V20z server usin

Pagina 28 - 2.4 BIOS Setup Utility

2-4 Sun Fire V20z Server User Guide • March 20042.4 BIOS Setup UtilityThe Basic Input Output System (BIOS) Setup utility is used to configure BIOS sett

Pagina 29 - 2.4.1 Main Menu

Chapter 2 Powering On and Configuring the Server 2-52.4.1 Main MenuTABLE 2-2 shows the options that are available from the BIOS Main menu.TABLE 2-2 BI

Pagina 30 - BIOS Main Menu (Continued)

iii Contents Preface vii1. Introduction to the Sun Fire V20z Server 1–1 1.1 Applications 1–21.2 Features 1–21.3 Server Management 1–31.3.1 Service Pr

Pagina 31 - 2.4.2 Advanced Menu

2-6 Sun Fire V20z Server User Guide • March 2004Primary MasterPrimary SlaveSecondary MasterSet the parameters of the IDE Primary Master/Slave and IDE

Pagina 32

Chapter 2 Powering On and Configuring the Server 2-72.4.2 Advanced MenuTABLE 2-3 shows the options that are available from the Advanced menu.TABLE 2-3

Pagina 33

2-8 Sun Fire V20z Server User Guide • March 2004Chipset Configuration Caution: Don’t change the settings unless you are sure of what you are doing. Set

Pagina 34

Chapter 2 Powering On and Configuring the Server 2-9• Bank Interleave: If set to Auto, bank interleaving is enabled if the memory size and type match.

Pagina 35

2-10 Sun Fire V20z Server User Guide • March 2004I/O Device ConfigurationOptions for peripheral menu. Options include:• PS/2 Mouse: Disabled prevents a

Pagina 36 - 2.4.3 Security Menu

Chapter 2 Powering On and Configuring the Server 2-11PCI ConfigurationSetup items for configuring the specific PCI device Slot #1 or Slot #2:• Option ROM

Pagina 37 - 2.4.4 Power Menu

2-12 Sun Fire V20z Server User Guide • March 20042.4.3 Security MenuTABLE 2-4 shows the options that are available from the BIOS Security menu.• Flow

Pagina 38 - 2.4.6 Exit Menu

Chapter 2 Powering On and Configuring the Server 2-132.4.4 Power MenuTABLE 2-5 shows the options that are available from the BIOS Power menu.Set User P

Pagina 39 - 2.4.7 Quick Boot Feature

2-14 Sun Fire V20z Server User Guide • March 20042.4.5 Boot MenuTABLE 2-6 shows the options that are available from the BIOS Boot menu. To change the

Pagina 40

Chapter 2 Powering On and Configuring the Server 2-152.4.7 Quick Boot FeatureThe QuickBoot feature, which disables BIOS memory tests, defaults to disab

Pagina 41

iv Sun Fire V20z Server User Guide • March 2004 2.4 BIOS Setup Utility 2–42.4.1 Main Menu 2–52.4.2 Advanced Menu 2–72.4.3 Security Menu 2–122.4.4 Pow

Pagina 42

2-16 Sun Fire V20z Server User Guide • March 20042.5 Booting to a USB Diskette DeviceOnly one diskette device is bootable on the Sun Fire V20z server.

Pagina 43 - FIGURE 1-1 for the location

3-1CHAPTER3Troubleshooting and DiagnosticsBefore troubleshooting your specific server problem, collect the following information: What events occurred

Pagina 44 - 816-7190-xx, for your system

3-2 Sun Fire V20z Server User Guide • March 20043.1 Preventative TroubleshootingCreating and following procedures can help prevent problems and make t

Pagina 45 - 3.4 Diagnostics

Chapter 3 Troubleshooting and Diagnostics 3-3 Most problems occur when something in the server has changed. When making changes to your server, follo

Pagina 46 - 817-5246-xx, for

3-4 Sun Fire V20z Server User Guide • March 20043.2.2 Internal Visual InspectionTo visually inspect the internal system, follow these steps:Note – Be

Pagina 47 - Module Test Devices

Chapter 3 Troubleshooting and Diagnostics 3-53.3 Troubleshooting UtilityYou can also use the Troubleshooting Dump Utility (TDU), which captures the fo

Pagina 48

3-6 Sun Fire V20z Server User Guide • March 20043.4.1 Mounting the Diagnostics TestsBefore running the Sun Fire V20z diagnostics tests, you need to mo

Pagina 49

Chapter 3 Troubleshooting and Diagnostics 3-7You can begin running diagnostics on the service processor while the platform diagnostics are loading. Yo

Pagina 50

3-8 Sun Fire V20z Server User Guide • March 2004fan speed.fan5 CPU 0 fan 1fan speed.fan6 CPU 0 fan 2memory adjacency.allDimms All DIMMsmemory dataline

Pagina 51 - 3.4.5 Viewing Test Results

Chapter 3 Troubleshooting and Diagnostics 3-9slag toggleLED.PCI-1 PCI 1 toggle LEDslag toggleLED.Power-Supply Power supply toggle LEDstorage long.ATA0

Pagina 52 - 3.4.6 Stopping Tests

Contents v 4.4.1 I/O Board 4–54.4.2 PCI Card 4–64.4.2.1 To Install a New PCI Card 4–64.4.2.2 To Remove an Existing PCI Card 4–74.4.3 SCSI Hard Disk D

Pagina 53 - Maintaining the Server

3-10 Sun Fire V20z Server User Guide • March 20043.4.4 Running Diagnostic TestsWhen running tests, you can choose to execute all tests or specify a sp

Pagina 54 - 4.1 Tools and Supplies Needed

Chapter 3 Troubleshooting and Diagnostics 3-11To run the diagnostics tests, type the following command:# diags run tests optionWhere the option is on

Pagina 55 - 4.3 Locations of Components

3-12 Sun Fire V20z Server User Guide • March 2004The following is an example of two passed test cases and one failed test case:3.4.6 Stopping TestsTo

Pagina 56 - Procedures

4-1CHAPTER4Maintaining the ServerThis chapter describes how to add, replace and configure components in the Sun Fire V20z server after it has been set

Pagina 57 - 4.4.1 I/O Board

4-2 Sun Fire V20z Server User Guide • March 20044.1 Tools and Supplies Needed #2 crosshead screwdriver Antistatic wrist strap (recommended) Alcohol

Pagina 58 - 4.4.2 PCI Card

Chapter 4 Maintaining the Server 4-34.3 Locations of ComponentsRefer to Figure 4-1 to locate components before performing the remove and replace proce

Pagina 59 - PCI Card and Riser

4-4 Sun Fire V20z Server User Guide • March 20044.4 Customer Replaceable Unit (CRU) ProceduresThe following components are customer replaceable: I/O

Pagina 60

Chapter 4 Maintaining the Server 4-54.4.1 I/O BoardFollow these steps to remove and replace the I/O board:1. Turn off the system, including any attach

Pagina 61

4-6 Sun Fire V20z Server User Guide • March 20044.4.2 PCI CardThe following procedure describes how to add or replace a PCI card. 1. Turn off the syst

Pagina 62 - 4.4.4 SCSI Backplane

Chapter 4 Maintaining the Server 4-7FIGURE 4-5 PCI Card Slot Cover4. Remove the card riser assembly from the PCI card connector on the motherboard. 5

Pagina 63 - Removing the CPU 1 VRM

vi Sun Fire V20z Server User Guide • March 2004 C.2 diags get tests C–4C.3 diags run tests C–5C.4 diags start C–7C.5 diags terminate C–8

Pagina 64 - Removing the SCSI Backplane

4-8 Sun Fire V20z Server User Guide • March 20044.4.3 SCSI Hard Disk Drive and CarrierThe following procedure describes how to remove and replace a SC

Pagina 65 - SCSI Backplane Jumper

Chapter 4 Maintaining the Server 4-94.4.3.1 Replacing a Hard Disk Drive in a Carrier1. Withdraw the carrier from the server as previously described.2.

Pagina 66 - slide the

4-10 Sun Fire V20z Server User Guide • March 20044.4.4 SCSI BackplaneThe following procedure describes how to replace the SCSI backplane. 1. Turn off

Pagina 67

Chapter 4 Maintaining the Server 4-115. Remove the center air baffle. FIGURE 4-11 Removing the Center Air Baffle6. Remove the second processor fan from

Pagina 68

4-12 Sun Fire V20z Server User Guide • March 20048. Disconnect the 5-pin power cable, the small flat cable, and the 68-pin ribbon signal cable from the

Pagina 69

Chapter 4 Maintaining the Server 4-13Note – When reinstalling the SCSI backplane, ensure that the jumper is installed as shown in Figure 4-16. FIGURE

Pagina 70 - 4.4.7 Power Supply

4-14 Sun Fire V20z Server User Guide • March 20044.4.5 CD-ROM/DVD/Floppy Disk Drive AssemblyThe following procedure describes how to replace the CD-RO

Pagina 71 - Removing the Power Supply

Chapter 4 Maintaining the Server 4-155. Unfasten the single screw securing the CD-ROM/DVD/Floppy Disk Drive assembly to the chassis (see Figure 4-19).

Pagina 72 - 4.4.8 Cooling Fans

4-16 Sun Fire V20z Server User Guide • March 20044.4.6 Operator Panel Board and DisplayThe following procedure describes how to replace the Operator P

Pagina 73 - Removing the Cooling Fans

Chapter 4 Maintaining the Server 4-176. Unfasten the ribbon cable connecting the operator panel board to the motherboard.Caution – Use care with the s

Pagina 74

vii Preface How This Book is Organized Chapter 1 contains an overview of the Sun Fire V20z server.Chapter 2 contains information on how to power on t

Pagina 75

4-18 Sun Fire V20z Server User Guide • March 20044.4.7 Power SupplyThe following procedure describes how to replace the power supply. 1. Turn off the

Pagina 76

Chapter 4 Maintaining the Server 4-195. Disconnect the three power supply cables from the motherboard.FIGURE 4-25 Disconnecting the Power Supply Cabl

Pagina 77 - 4.4.11 Memory Modules

4-20 Sun Fire V20z Server User Guide • March 20044.4.8 Cooling FansThe following procedure describes how to replace a cooling fan. 1. Press the power

Pagina 78

Chapter 4 Maintaining the Server 4-216. Unplug the fan’s power connector from the motherboard.FIGURE 4-29 Removing the Cooling Fans7. Pull the fan st

Pagina 79 - 4.4.12 System Battery

4-22 Sun Fire V20z Server User Guide • March 20044.4.9 Memory Voltage Regulator ModulesThe following procedure describes how to replace a memory volta

Pagina 80 - Removing the System Battery

Chapter 4 Maintaining the Server 4-234.4.10 CPU Voltage Regulator ModulesThe following procedure describes how to remove and replace a CPU voltage reg

Pagina 81 - 4.4.13 Cable Kit

4-24 Sun Fire V20z Server User Guide • March 2004To replace a CPU VRM:1. Press the new VRM into the empty socket until it snaps into place, ensuring

Pagina 82 - Cable Connectors

Chapter 4 Maintaining the Server 4-254.4.11 Memory ModulesThe following procedure describes how to remove and replace memory modules. To remove a mem

Pagina 83 - 4.4.14 CPUs

4-26 Sun Fire V20z Server User Guide • March 2004To install a memory module:1. Ensure that the memory module socket’s ejectors are open (rotated outw

Pagina 84

Chapter 4 Maintaining the Server 4-274.4.12 System BatteryThe system battery is a 3.0-volt standard 20 mm Lithium coin-cell battery. You may need to r

Pagina 85

viii Sun Fire V20z Server User Guide • March 2004 Shell Prompts Typographic Conventions Shell Prompt C shell machine-name % C shell superuser machi

Pagina 86

4-28 Sun Fire V20z Server User Guide • March 20044. Remove the system battery by sliding it back and prying it from the holder. FIGURE 4-37 Removing

Pagina 87 - 4.4.15 Super CRU

Chapter 4 Maintaining the Server 4-294.4.13 Cable KitThe following procedure describes how to remove and replace the following cables:1. Five-pin cabl

Pagina 88 - CPUs and Heatsinks (1-2)

4-30 Sun Fire V20z Server User Guide • March 2004The two halves of the 5-pin SCSI backplane power cable connector (1) are secured with a hook. The 68-

Pagina 89 - System Specifications

Chapter 4 Maintaining the Server 4-314.4.14 CPUsThe following procedure describes how to replace a CPU. 4.4.14.1 Removing a Heatsink and CPU1. Turn of

Pagina 90 - A.2 Power Specifications

4-32 Sun Fire V20z Server User Guide • March 20045. Unfasten the two securing screws and remove the heatsink securing clip. FIGURE 4-43 Removing the

Pagina 91 - BIOS POST Codes

Chapter 4 Maintaining the Server 4-334.4.14.2 Installing a CPU and Heatsink1. Unpack the new CPU. Caution – Observe the appropriate ESD precautions.2.

Pagina 92 - BIOS POST Codes (Continued)

4-34 Sun Fire V20z Server User Guide • March 200410. Ensure the foam strip under the heatsink area is intact and has not been removed, loosened, or da

Pagina 93

Chapter 4 Maintaining the Server 4-354.4.15 Super CRUThe Super CRU is a chassis containing all of the system components, except those designated as cu

Pagina 94

4-36 Sun Fire V20z Server User Guide • March 2004 Memory Modules (1-8) CPUs and Heatsinks (1-2)Note – You must remove the center air baffl e (with th

Pagina 95

A-1APPENDIXASystem SpecificationsTo obtain maximum reliability and performance, install your Sun Fire V20z server into a proper environment and ensure

Pagina 96 - Boot Block in Flash ROM

Preface ix Related Documentation Accessing Sun Documentation You can view, print, or purchase a broad selection of Sun documentation, including local

Pagina 97 - Post Code Description

A-2 Sun Fire V20z Server User Guide • March 2004A.2 Power SpecificationsA.3 Environmental SpecificationsTABLE A-2 Sun Fire V20z Server AC Input Specific

Pagina 98

B-1APPENDIXBBIOS POST CodesTypically, the BIOS displays warning or error messages on the video display in the event of hardware or configuration errors

Pagina 99 - Diagnostics Commands

B-2 Sun Fire V20z Server User Guide • March 20040E Initialize I/O component0F Initialize the local bus IDE10 Initialize power management11 Load alter

Pagina 100 - C.1 diags cancel tests

Appendix B BIOS POST Codes B-341 Initialize extended memory for RomPilot42 Initialize interrupt vectors45 POST device initialization46 Check ROM copyr

Pagina 101 - C.1.3 diags get state

B-4 Sun Fire V20z Server User Guide • March 20046B Load custom defaults (optional)6C Display shadow area message6E Display possible high address for U

Pagina 102 - C.2 diags get tests

Appendix B BIOS POST Codes B-598 Search for option ROMs 99 Check for SMART drive (optional)9A Shadow option ROMs9C Set up power management 9D Initiali

Pagina 103 - C.3 diags run tests

B-6 Sun Fire V20z Server User Guide • March 2004TABLE B-2 shows the POST codes for the boot block in Flash ROM.C2 Initialize error loggingC3 Initiali

Pagina 104 - C.3.2 Return Codes

Appendix B BIOS POST Codes B-7EC Initialize Memory type ED Initialize Memory size EE Shadow Boot BlockEF System memory test F0 Initialize interrupt ve

Pagina 105 - C.4 diags start

B-8 Sun Fire V20z Server User Guide • March 2004

Pagina 106 - C.5 diags terminate

C-1APPENDIXCDiagnostics CommandsYou can use the diags subcommands shown in TABLE C-1 to manage diagnostics tests:Note – Every command returns a return