Sun-microsystems Sun StorEdge T3 Manuale Utente

Navigare online o scaricare Manuale Utente per Hardware Sun-microsystems Sun StorEdge T3. Sun Microsystems Sun StorEdge T3 User Manual Manuale Utente

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 88
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 0
Sun Microsystems, Inc.
901 San Antonio Road
Palo Alto, CA 94303-4900 U.S.A.
650-960-1300
Send comments about this document to: [email protected]
Sun StorEdge
T3 and T3+ Array
Configuration Guide
Part No. 816-0777-10
August 2001, Revision A
Vedere la pagina 0
1 2 3 4 5 6 ... 87 88

Sommario

Pagina 1 - Configuration Guide

Sun Microsystems, Inc.901 San Antonio RoadPalo Alto, CA 94303-4900 U.S.A.650-960-1300Send comments about this document to: [email protected] Stor

Pagina 2

x Sun StorEdge T3 and T3+ Array Configuration Guide • August 2001Using UNIX CommandsThis document contains some information on basic UNIX®commands and

Pagina 3 - Contents

Preface xiShell PromptsRelated DocumentationShell PromptC shell machine_name%C shell superuser machine_name#Bourne shell and Korn shell $Bourne shell

Pagina 4

xii Sun StorEdge T3 and T3+ Array Configuration Guide • August 2001Accessing Sun Documentation OnlineYou can find the Sun StorEdge T3 and T3+ array do

Pagina 5 - Contents v

1CHAPTER1Array Configuration OverviewThis chapter describes the Sun StorEdge T3 and T3+ arrays, the connection ports,and Fibre Channel connections. It

Pagina 6 - Glossary 65

2 Sun StorEdge T3 and T3+ Array Configuration Guide • August 2001The array can be used either as a standalone storage unit or as a building block,inte

Pagina 7

Chapter 1 Array Configuration Overview 3FIGURE 1-1 Sun StorEdge T3 Array Controller Card and PortsThe Sun StorEdge T3+ array controller card contains:

Pagina 8

4 Sun StorEdge T3 and T3+ Array Configuration Guide • August 2001FIGURE 1-2 Sun StorEdge T3+ Array Controller Card and PortsInterconnect CardsThe inte

Pagina 9 - How This Book Is Organized

Chapter 1 Array Configuration Overview 5FIGURE 1-3 Interconnect Card and PortsInterconnect cardsInputOutput

Pagina 10 - Typographic Conventions

6 Sun StorEdge T3 and T3+ Array Configuration Guide • August 2001Array ConfigurationsEach array uses Fibre Channel-Arbitrated Loop (FC-AL) connections

Pagina 11 - Related Documentation

Chapter 1 Array Configuration Overview 7FIGURE 1-5 Enterprise ConfigurationNote – Sun StorEdge T3 array workgroup and enterprise configurations requir

Pagina 12 - Sun Welcomes Your Comments

PleaseRecycleCopyright 2001 Sun Microsystems, Inc., 901 San Antonio Road, Palo Alto, CA 94303-4900 U.S.A. All rights reserved.This product or document

Pagina 13 - Array Configuration Overview

8 Sun StorEdge T3 and T3+ Array Configuration Guide • August 2001Configuration Guidelines andRestrictionsWorkgroup Configurations: The media access c

Pagina 14 - Controller Card

Chapter 1 Array Configuration Overview 9Configuration Recommendations Use enterprise configurations for controller redundancy. Use host-based softwa

Pagina 15 - FC-AL data connection port

10 Sun StorEdge T3 and T3+ Array Configuration Guide • August 2001Supported SoftwareThe following software is supported on Sun StorEdge T3 and T3+ arr

Pagina 16 - Interconnect Cards

Chapter 1 Array Configuration Overview 11 Switches are not supported. Hubs must be used. The Sun StorEdge SBus FC-100 (SOC+) HBA and the onboard SO

Pagina 17 - Interconnect cards

12 Sun StorEdge T3 and T3+ Array Configuration Guide • August 2001

Pagina 18 - Array Configurations

13CHAPTER2Configuring Global ParametersWhen an array is shipped, the global parameters are set to default values. Thischapter describes how to reconfi

Pagina 19

14 Sun StorEdge T3 and T3+ Array Configuration Guide • August 2001Configuring Cache for Performance andRedundancyCache mode can be set to the followin

Pagina 20 - Restrictions

Chapter 2 Configuring Global Parameters 15Configuring Data Block SizeThe data block size is the amount of data written to each drive when striping dat

Pagina 21 - Supported Platforms

16 Sun StorEdge T3 and T3+ Array Configuration Guide • August 2001Note – The data block size must be configured before any logical volumes arecreated

Pagina 22 - Sun Cluster Support

Chapter 2 Configuring Global Parameters 17Note – Individual physical disk drives are not visible from the application host.Refer to the Sun StorEdge T

Pagina 23

iiiContentsPreface ix1. Array Configuration Overview 1Product Description 1Controller Card 2Interconnect Cards 4Array Configurations 6Configuration Gu

Pagina 24

18 Sun StorEdge T3 and T3+ Array Configuration Guide • August 2001 Data-intensive NFS, version 3 DSS DW HPCNote – If you are creating new volumes

Pagina 25 - Configuring Global Parameters

Chapter 2 Configuring Global Parameters 19Note – Only one hot spare is allowed per array and it is only usable for the array inwhich it is configured.

Pagina 26 - Redundancy

20 Sun StorEdge T3 and T3+ Array Configuration Guide • August 2001If the volume has a hot spare configured and that drive is available, the data on th

Pagina 27 - Selecting a Data Block Size

Chapter 2 Configuring Global Parameters 21 Second, you can use third-party software on the host system to create as manypartitions as desired from a

Pagina 28 - Logical Volumes

22 Sun StorEdge T3 and T3+ Array Configuration Guide • August 2001Configuring RAID LevelsThe Sun StorEdge T3 and T3+ arrays are preconfigured at the f

Pagina 29

23CHAPTER3Configuring Partner GroupsSun StorEdge T3 and T3+ arrays can be interconnected in partner groups to form aredundant and larger storage syste

Pagina 30

24 Sun StorEdge T3 and T3+ Array Configuration Guide • August 2001FIGURE 3-1 Sun StorEdge T3 Array Partner GroupNote – Sun StorEdge T3 arrays require

Pagina 31

Chapter 3 Configuring Partner Groups 25Any controller unit will boot from the master controller unit’s drives. Allconfiguration data, including syslog

Pagina 32

26 Sun StorEdge T3 and T3+ Array Configuration Guide • August 2001Creating Partner GroupsPartner groups can be created in two ways: From new units F

Pagina 33

27CHAPTER4Configuration ExamplesThis chapter includes sample reference configurations for Sun StorEdge T3 and T3+arrays. Although there are many suppo

Pagina 34 - Configuring RAID Levels

iv Sun StorEdge T3 and T3+ Array Configuration Guide • August 2001Logical Volumes 16Guidelines for Configuring Logical Volumes 17Determining How Many

Pagina 35 - Configuring Partner Groups

28 Sun StorEdge T3 and T3+ Array Configuration Guide • August 2001Single Host With One Controller UnitFIGURE 4-1 shows one application host connected

Pagina 36

Chapter 4 Configuration Examples 29Single Host With Two Controller UnitsConfigured as a Partner GroupFIGURE 4-2 shows one application host connected t

Pagina 37 - How Partner Groups Work

30 Sun StorEdge T3 and T3+ Array Configuration Guide • August 2001Host Multipathing Management SoftwareWhile Sun StorEdge T3 and T3+ arrays are redund

Pagina 38 - Creating Partner Groups

Chapter 4 Configuration Examples 31Single Host With Four Controller UnitsConfigured as Two Partner GroupsFIGURE 4-4 shows one application host connect

Pagina 39 - Configuration Examples

32 Sun StorEdge T3 and T3+ Array Configuration Guide • August 2001Single Host With Eight Controller UnitsConfigured as Four Partner GroupsFIGURE 4-5 s

Pagina 40

Chapter 4 Configuration Examples 33FIGURE 4-5 Single Host With Eight Controller Units Configured as Four Partner GroupsApplication hostManagement host

Pagina 41 - Configured as a Partner Group

34 Sun StorEdge T3 and T3+ Array Configuration Guide • August 2001Hub Host ConnectionThe following sample configurations are included in this section:

Pagina 42

Chapter 4 Configuration Examples 35The following three parameters must be set on the master controller unit, as follows: mp_support = rw or mpxio ca

Pagina 43 - ■ cache mirroring = auto

36 Sun StorEdge T3 and T3+ Array Configuration Guide • August 2001Single Host With Two Hubs and Eight ControllerUnits Configured as Four Partner Group

Pagina 44

Chapter 4 Configuration Examples 37FIGURE 4-7 Single Host With Two Hubs Configured and Eight Controller Units as FourPartner GroupsHubHubInterconnectc

Pagina 45

Contents vSingle Host With Two Hubs and Eight Controller Units Configured as FourPartner Groups 36Dual Hosts With Two Hubs and Four Controller Units 3

Pagina 46 - Hub Host Connection

38 Sun StorEdge T3 and T3+ Array Configuration Guide • August 2001Dual Hosts With Two Hubs and Four ControllerUnitsFIGURE 4-8 shows two application ho

Pagina 47

Chapter 4 Configuration Examples 39FIGURE 4-8 Dual Hosts With Two Hubs and Four Controller UnitsHubHubApplication host 1EthernetportLANFC-ALHBAHBAHBAH

Pagina 48

40 Sun StorEdge T3 and T3+ Array Configuration Guide • August 2001Dual Hosts With Two Hubs and Eight ControllerUnitsFIGURE 4-9 shows two application h

Pagina 49

Chapter 4 Configuration Examples 41FIGURE 4-9 Dual Hosts With Two Hubs and Eight Controller UnitsApplication host 1Management HostEthernetportLANFC-AL

Pagina 50

42 Sun StorEdge T3 and T3+ Array Configuration Guide • August 2001Dual Hosts With Two Hubs and Four ControllerUnits Configured as Two Partner GroupsFI

Pagina 51

Chapter 4 Configuration Examples 43FIGURE 4-10 Dual Hosts With Two Hubs and Four Controller Units Configured as TwoPartner GroupsHubHubApplication hos

Pagina 52

44 Sun StorEdge T3 and T3+ Array Configuration Guide • August 2001Dual Hosts With Two Hubs and Eight ControllerUnits Configured as Four Partner Groups

Pagina 53

Chapter 4 Configuration Examples 45FIGURE 4-11 Dual Hosts With Two Hubs and Eight Controller Units Configured as FourPartner GroupsApplication host 1M

Pagina 54

46 Sun StorEdge T3 and T3+ Array Configuration Guide • August 2001Switch Host ConnectionThis section contains the following example configurations: “

Pagina 55

Chapter 4 Configuration Examples 47FIGURE 4-12 Dual Hosts With Two Switches and Two Controller UnitsApplication host AApplication host BEthernetportMa

Pagina 56

vi Sun StorEdge T3 and T3+ Array Configuration Guide • August 2001Administration Path 60Connecting Partner Groups 60Workgroup Configurations 62Enterpr

Pagina 57

48 Sun StorEdge T3 and T3+ Array Configuration Guide • August 2001Dual Hosts With Two Switches and EightController UnitsFIGURE 4-13 shows two applicat

Pagina 58 - Switch Host Connection

Chapter 4 Configuration Examples 49FIGURE 4-13 Dual Hosts With Two Switches and Eight Controller UnitsApplication host 1Application host 2Ethernetport

Pagina 59

50 Sun StorEdge T3 and T3+ Array Configuration Guide • August 2001

Pagina 60 - Controller Units

51CHAPTER5Host ConnectionsThis chapter describes the host bus adapters (HBAs) that are supported by SunStorEdge T3 and T3+ arrays: “Sun Enterprise SB

Pagina 61

52 Sun StorEdge T3 and T3+ Array Configuration Guide • August 2001Sun Enterprise SBus+ and Graphics+I/O BoardsThe SBus+ and Graphics+ I/O boards each

Pagina 62

Chapter 5 Host Connections 53Sun StorEdge PCI FC-100 Host BusAdapterThe Sun StorEdge PCI FC-100 host bus adapter is a 33-MHz, 100 Mbytes/second,single

Pagina 63 - Host Connections

54 Sun StorEdge T3 and T3+ Array Configuration Guide • August 2001Sun StorEdge SBus FC-100 Host BusAdapterThe Sun StorEdge SBus FC-100 host bus adapte

Pagina 64 - I/O Boards

Chapter 5 Host Connections 55Sun StorEdge PCI Single Fibre ChannelNetwork AdapterThe Sun StorEdge PCI Single Fibre Channel network adapter is a Fibre

Pagina 65 - System Requirements

56 Sun StorEdge T3 and T3+ Array Configuration Guide • August 2001Sun StorEdge PCI Dual Fibre ChannelNetwork AdapterThe Sun StorEdge PCI Dual Fibre Ch

Pagina 66

Chapter 5 Host Connections 57Sun StorEdge CompactPCI Dual FibreChannel Network AdapterThe Sun StorEdge CompactPCI Dual Fibre Channel network adapter h

Pagina 67 - Network Adapter

viiFiguresFIGURE 1-1 Sun StorEdge T3 Array Controller Card and Ports 3FIGURE 1-2 Sun StorEdge T3+ Array Controller Card and Ports 4FIGURE 1-3 Intercon

Pagina 68

58 Sun StorEdge T3 and T3+ Array Configuration Guide • August 2001

Pagina 69 - Channel Network Adapter

59CHAPTER6Array CablingThis chapter describes the array configurations supported by the Sun StorEdge T3and T3+ arrays, and it includes the following s

Pagina 70

60 Sun StorEdge T3 and T3+ Array Configuration Guide • August 2001 Switch connection where the FC-AL from the array is connected to a switch onthe sa

Pagina 71 - Array Cabling

Chapter 6 Array Cabling 61FIGURE 6-1 Sun StorEdge T3 Array Controller Card and Interconnect CardsFIGURE 6-2 Sun StorEdge T3+ Array Controller Card and

Pagina 72 - Connecting Partner Groups

62 Sun StorEdge T3 and T3+ Array Configuration Guide • August 2001Workgroup ConfigurationsThe following configuration rules apply to array workgroup c

Pagina 73 - Chapter 6 Array Cabling 61

Chapter 6 Array Cabling 63Enterprise ConfigurationsThe following rules configuration rules apply to enterprise (partner group)configurations (FIGURE 6

Pagina 74 - Workgroup Configurations

64 Sun StorEdge T3 and T3+ Array Configuration Guide • August 2001

Pagina 75 - Enterprise Configurations

65GlossaryAadministrativedomain Partner groups (interconnected controller units) that share commonadministration through a master controller.alternate

Pagina 76

66 Sun StorEdge T3 and T3+ Array Configuration Guide • August 2001Ccommand-line interface(CLI) The interface between the Sun StorEdge T3 and T3+ array

Pagina 77 - Glossary

67FFibre ChannelArbitrated Loop(FC-AL) A 100 Mbyte/s serial channel that enables connection of multiple devices (diskdrives and controllers).field-rep

Pagina 78

viii Sun StorEdge T3 and T3+ Array Configuration Guide • August 2001FIGURE 5-1 Sun Enterprise 6x00/5x00/4x00/3x00 SBus+ I/O Board 52FIGURE 5-2 Sun Sto

Pagina 79

68 Sun StorEdge T3 and T3+ Array Configuration Guide • August 2001Iinput/output operationsper second (IOPS) A performance measurement of the transacti

Pagina 80

69multi-initiatorconfiguration A supported array configuration that connects two hosts to one or more arrayadministrative domains through hub or switc

Pagina 81

70 Sun StorEdge T3 and T3+ Array Configuration Guide • August 2001reverse addressresolution protocol(RARP) A utility in the Solaris operating environm

Pagina 82

71Wworkgroupconfiguration A standalone array connected to a host system.world wide name(WWN) A number used to identify array volumes in both the array

Pagina 83

72 Sun StorEdge T3 and T3+ Array Configuration Guide • August 2001

Pagina 84

73IndexAadministration path, 60alternate master controller unitin a partner group, 7Alternate Pathing (AP)in configuration recommendations, 9in partner

Pagina 85

74 Sun StorEdge T3 and T3+ Array Configuration Guide • August 2001Eenterprise configurationconfiguration rules, 63description, 6See partner groupEtherne

Pagina 86

Index 75sharing parameter settings, 9using AP, 30using DMP, 30using multipathing software, 30platforms supported, 9RRAIDand applications, 18configuring

Pagina 87 - Index 75

76 Sun StorEdge T3 and T3+ Array Configuration Guide • August 2001

Pagina 88

ixPrefaceThe Sun StorEdge T3 and T3+ Array Configuration Guide describes the recommendedconfigurations for Sun StorEdge T3 and T3+ arrays for high ava

Commenti su questo manuale

Nessun commento