6 Netra 1290 Server Installation Guide May 2006
Adjust the rear bracket or the adjustable bracket position to modify the length of the
assembly. The slide rail assembly and the rear bracket have bracket locations for
specific cabinets stamped onto the metal.
FIGURE 1-3 shows the location of the
markings.
To Install the Inner Rails on the Server
1. Remove the inner rail from the slide rail assembly:
a. Press the latch adjacent to the green latch.
b. Pull the inner rail free from the outer slide rail assembly.
2. Push up on the inner rail so that the locating tab, on the side of the server, clips
over the cutouts in the rail (
FIGURE 1-4).