Chapter 1 Overview 1-3
1.2 PICMG Standards Compliance
The ARTM-HD is fully compliant with the PICMG
®
2.0 Revision 3.1 specification.
1.2.1 Maximum Power Dissipation
The maximum power dissipation is 25 Watts.
1.2.2 Airflow Cooling Requirements
TABLE 1-1 lists the airflow cooling requirements based on a maximum power of 25W,
which is the only power level available on this ARTM-HD.
TABLE 1-1 Airflow Cooling Requirements
Meters Cubed Per Minute (M
3
/min) Feet Cubed Per Minute (CFM)
25 28 40 55 25 28 40 55