Sun-microsystems Sun StorEdge A3500FC Manuale Utente Pagina 61

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 62
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 60
A-1
APPENDIX
A
Sun StorEdge A3500 and A3500FC
Specifications
A.1 Initial Cold Start Surge Current
Specifications
The following tables provide the initial cold start surge specifications for the
StorEdge A3500 and A3500FC systems.
TABLE A-1 Device Surge Current Specifications
Device Specification for Each Power Supply
StorEdge A3x00 controller module 25A rms or 35A peak for one line cycle
RSM
disk array 15A rms or 21A peak for one line cycle
StorEdge D1000 disk array 11A rms or 22A peak for one line cycle
Vedere la pagina 60