Chapter 3 Installing the Front-Access Adapter 39
3. During the power on sequence, watch the hot-swap LED on the adapter
(
FIGURE 3-7).
The LED should blink quickly and then stay off if the adapter was installed
correctly.
If the hot-swap LED remains on (lit), the adapter was not installed correctly. The
adapter may not be seated correctly in the slot. You will need to remove and
reinstall the adapter using the cold-swap procedures to make sure that it sits
correctly in the slot:
Power off the server
Remove and replace the adapter
Power on the server
Refer to the server’s documentation for additional troubleshooting instructions.
4. Verify that the servers power LED is on (lit), indicating that the server has
completely powered on.
Refer to the server’s documentation for the location of the power LED. For example,
on a Netra ct server, the power LED is on the front panel.