62 Sun Quad FastEthernet 6U CompactPCI Adapter Installation and User’s Guide June 2000
Operational Mode Parameters
TABLE B-5 describes the operational mode parameters and their default values.
Note The priority (in descending order) for these parameters is:
adv_100fdx_cap, adv_100T4_cap, adv_100hdx_cap, adv_10fdx_cap, and
adv_10hdx_cap.
TABLE B-5 Operational Mode Parameters
Parameter Description
adv_autoneg_cap Local transceiver capability advertised by the hardware
0 = Forced mode
1 = Autonegotiation (default)
adv_100fdx_cap Local transceiver capability advertised by the hardware; read/write parameter
0 = Not 100 Mbit/sec full-duplex capable
1 = 100 Mbit/sec full-duplex capable (default)
adv_100hdx_cap Local transceiver capability advertised by the hardware; read/write parameter
0 = Not 100 Mbit/sec half-duplex capable
1 = 100 Mbit/sec half-duplex capable (default)
adv_10fdx_cap Local transceiver capability advertised by the hardware; read/write parameter
0 = Not 10 Mbit/sec full-duplex capable (default)
1 = 10 Mbit/sec full-duplex capable
adv_10hdx_cap Local transceiver capability advertised by the hardware; read/write parameter
0 = Not 10 Mbit/sec half-duplex capable
1 = 10 Mbit/sec half-duplex capable (default)